Upper range – Humminbird 500 SERIES 596C User Manual

Page 42

Advertising
background image

34

Upper Range

(Advanced: Sonar and Big Digits Views only)

Upper Range sets the shallowest depth range that

will be displayed on the Sonar and Big Digits Views. The Upper Range menu
option is available when User Mode is set to Advanced (see Main Menu: User
Mode
) and can only be accessed from the Sonar and Big Digits Views. Upper
Range is often used with Lower Range.

NOTE: A minimum distance of 10 feet will be maintained between the Upper and
Lower Range regardless of the manual settings entered.

To adjust the Upper Range:

1. Make sure the User Mode is set to Advanced, then highlight Upper

Range on the Sonar X-Press™ Menu.

NOTE: See Main Menu: User Mode to change the User Mode to Advanced.

2. Press the RIGHT or LEFT Cursor keys to increase or decrease the Upper

Range setting. (0 to 990 feet or 0 to 327 meters [International Models
only]
, Default = 0)

For example, if you are only interested in the area between 20 and 50 feet deep,

you should set the Upper Depth Range to 20 and the Lower Depth Range to 50.
The Sonar View will then show the 30 foot area between 20 and 50 and will not
show the surface or the bottom (assuming the bottom is deeper than 50 feet).
Greater detail will be shown for the area between 20 and 50 feet.

Sonar X-Press™ Menu

Advertising
This manual is related to the following products: