Heath Zenith Motion Sensor Light Control UT-5105-WH User Manual

Motion sensor light control, Operation, Features

Advertising
background image

Motion Sensor Light
Control

© 2007 HeathCo LLC

598-1292-03

Light Control

Sensor

Cover

Plate

Bulb Holders

2 Wire

Connectors

6 Screws

(3 sizes included)

Gasket

2 Shells

Questions or problems? Before returning to your re-
tailer, refer to the troubleshooting guide in this manual
or call our technical service department at 1-800-858-
8501 (English speaking only), 7:30 am to 4:30 pm, CST,
Monday – Friday.

Features

• D

ual

Z

one

™ Technology.

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• D

ual

B

rite

®

Timer.

• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

Requirements

• The light control requires 120-volts AC.
• If you want to use the Manual Mode, the control must

be wired through a switch.

Some codes require installation by a qualified
electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Mounting Bolt

Mounting Strap

Rubber Plug

Plastic Hanger

TEST

TEST 1 5 20

ON-TIME

Off 3 6 Dusk to

Dawn

D

ual

B

rite

®

Put ON-TIME switch
on the sensor bottom
to TEST and the D

ual

-

B

rite

®

switch OFF.

OPERATION

* resets to Auto Mode at dawn.

MANUAL MODE

ON-TIME

TEST

1 5 20

... back on.

AUTO

1 Second OFF

then...

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Package Contents

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.

Put the ON-TIME switch in the 1, 5,
or 20 minute position.

Items

Models

247580

UT-5105-BZ

182155

UT-5105-WH

Mode:

On-Time

Works:

Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 20 Min

x

Manual

To Dawn*

x

Accent

3, 6 Hr, to Dawn

x

Meets the ENERGY STAR

®

guidelines

when D

ual

B

rite

®

function is off and

ON-TIME is 1 or 5 minutes and when
used with 120 W Max bulbs.