Installation – Heath Zenith Motion Sensor Light Control UT-5105-WH User Manual

Page 2

Advertising
background image

2

598-1292-03

INSTALLATION

Estimated Installation Time: 30 minutes
Items needed for installation (not included):
• Phillips and flathead screwdrivers
• Pliers

• Wire strippers/cutters

• Safety glasses • Light bulbs
• Silicone caulk • Ladder
• Black tape

For eave mount only:

Swing the sensor head towards the clamp screw

joint.

If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.

Then rotate the sensor head clockwise 180° so

the controls face down.

Wall Mount

Eave Mount

For under eave installation, the sensor head must
be rotated
as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.

Controls

Clamp Screw

Controls

Controls

Move ON-TIME Switch to

1, 5, or 20 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

WARNING: Turn power off at circuit breaker

or fuse.

For easy installation, select an existing light with a wall
switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m)
above the ground.

NOTE: If fixture is mounted higher than

8 ft. (2.4 m), aiming the sensor down will reduce coverage
distance.

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

D

ual

B

rite

®

Timer

Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.