Hearth and Home Technologies SL-550TRSI-AUE User Manual

Page 34

Advertising
background image

Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06

34

Inspect

Maintenance Tasks

Doors

1. Inspect for scratches, dents or other damage and repair as necessary.

2. Verify no obstructions to airflow .

3. Verify maintenance of proper clearance to combustible household objects.

Gasket Seal, Glass
Assembly and Glass

1. Inspect gasket seal and its condition.

2. Inspect glass panels for scratches and nicks that can lead to breakage when exposed to

heat.

3. Confirm there is no damage to glass or glass frame. Replace as necessary.

4. Verify that latches engage properly, clip studs are not stripped, and glass attachment

components are intact and operating properly. Replace as necessary.

5. Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot

be removed.

Valve Compartment

and Firebox Top

1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these
areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.

2. Remove any foreign objects.

3. Verify unobstructed air circulation.

Logs

1. Inspect for broken, damaged, or missing logs. Replace as necessary.

2. Verify correct log placement and no flame impingement causing sooting. Correct as

necessary.

Firebox

1. Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as
necessary.

2. Replace gas fireplace if firebox has been perforated.

Burner Ignition and
Operation

1. Verify burner is properly secured and aligned with pilot or igniter.

2. Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if

necessary.

3. Replace ember materials with new dime-size and shape pieces. Do not block ports or

obstruct lighting paths.

4. Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

5. Inspect for lifting or other flame problems.

6. Inspect orifice for soot, dirt or corrosion.

7. Verify manifold and inlet pressures. Adjust regulator as required.

8. Inspect pilot flame strength. Clean or replace orifice as necessary.

9. Inspect thermocouple for soot, corrosion and deterioration. Clean with emery cloth or

replace as required.

Flueing

1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

2. Confirm that termination cap remains clear and unobstructed by plants, etc.
3. Verify that termination cap clearance to subsequent construction (building additions, decks,
fences or sheds) has been maintained.
4. Inspect for corrosion or separation.

5. Verify weather stripping, sealing and flashing remains intact.

Remote controls

1. Verify operation of remote.

2. Replace batteries in remote transmitters and battery-powered receivers.

3.5

MAINTENANCE TASKS

Advertising