Stopping generator, High altitude operation, Powering appliances – Honeywell HW5500E User Manual

Page 23

Advertising
background image

HW5500/5500E Portable Generator Owner’s Manual

www.honeywellgenerators.com

17

Stopping Generator

6.

Grip recoil starter handle and pull slowly until you feel
slight resistance.

7.

Apply a swift, single pull to start engine. Carefully
return recoil starter handle to original position.

8.

As engine warms up, and RPM stabilizes, gradually
push in choke control to OFF position.

Stopping Generator

In an emergency:

Press and hold engine control switch to STOP position
until engine stops.

In normal use:

1.

Turn OFF any connected appliances and unplug any
connected power cords.

2.

Allow generator to run for 2-3 minutes.

3.

Press engine control switch to STOP position.

4.

Turn fuel valve to OFF position.

High Altitude Operation

At high altitudes, standard carburetor air-fuel mixture will
be excessively rich. Performance will decrease and fuel
consumption will increase.

High altitude performance can be improved by installing a
smaller diameter main fuel jet in the carburetor and then
readjusting the pilot screw. If you always operate the
engine at altitudes higher than 5000 feet (1500 meters)
above sea level, have an authorized generator dealer per-
form this carburetor modification.

Even with suitable carburetor jetting, engine horsepower
will decrease approximately 3.5% for each 1000 foot (300
meter) increase in altitude. The effect of altitude on horse-

power will be greater than this if no carburetor modifica-
tion is made.

Powering Appliances

NOTE:

i
In this manual, the term “appliance” refers to any electri-
cal device that can be connected to generator for power.

Rules for Powering Appliances

Plan carefully: Before using generator to power
appliances, take time to add power rating (watts) of
each appliance and verify that total wattage does not
exceed rated output of generator. Power rating infor-
mation can usually be found on an appliance’s prod-
uct label, or stamped inside or on back of appliance.
See Tablea1 for a listing of average appliance wattage
requirements.

NEVER overload: Circuit breakers will stop flow of
electricity between generator and appliance if genera-
tor is overloaded. This will be indicated by a “tripped”
breaker. If this happens, power off and disconnect
appliance(s), wait a few minutes, and then push to
reset circuit breaker.

Pay attention to appliance operation: If appliance
begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it OFF immediately. Disconnect
appliance and determine whether problem is appli-
ance, or if rated load capacity of generator has been
exceeded.

Use suitable extension cords: If using an extension
cord to connect appliance to generator, use only UL-
listed, three-prong extension cords. Be sure exten-

FIGURE 22: Recoil Starter Handle

To prevent damage to generator, do not allow starter grip to
snap back against engine.

If engine jetted for high altitude is used at lower altitude, lean
air fuel mixture will reduce performance and may over-heat
and seriously damage the engine.

NEVER start generator with electrical appliances plugged in
and turned on.

Faulty appliances and power cords can result in elec-
trical shock.

• Before attempting to power an appliance, be sure genera-

tor has been properly grounded, and that appliance and
power cord are in good working order.

Advertising