Condensing unit – Hoshizaki KMS-1400MLH User Manual

Page 10

Advertising
background image

10

The condensing unit must be positioned in a permanent site under the following guidelines:
• A firm and flat site.
• A dry and well ventilated area with 24" (61 cm) clearance in both front and rear for proper

air circulation and ease of maintenance and/or service should they be required. See
Fig. 1.

• The maximum line length is 55 feet.

Note: If the recommended guidelines of the installation are exceeded, the icemaker

performance may be reduced.

CAUTION

Failure to install the equipment within these guidelines may adversely affect
performance, component life, and warranty coverage.

2. Condensing Unit

IMPORTANT

This condensing unit is intended for outdoor use. Normal operating ambient
temperature should be within -20°F to +122°F (-29°C to 50°C). Operation of
the unit, for extended periods, outside of these normal temperature ranges may
affect icemaker performance.

The icemaker must be coupled with the appropriate condensing unit as listed below.

Air

Air

Minimum " (1 cm) Clearance

Fig. 1

Icemaker

Hoshizaki Condensing Unit

KMS-100MLH

SRK-1H/

Advertising