Switch fabric-channel trunk, Syntax, Example – Fortinet 5003 User Manual

Page 101: Config switch fabric-channel trunk

Advertising
background image

FortiSwitch-5003A CLI reference

config

FortiSwitch-5003A and 5003 Fabric and Base Backplane Communications Guide
01-30000-85717-20081205

101

switch fabric-channel trunk

Use this command to create a trunk and add FortiSwitch-5003A interfaces to the trunk. You use trunks
to group FortiSwitch-5003A interfaces so that you can use 802.3ad static mode layer-2 link
aggregation to distribute sessions to the fabric interfaces of the FortiGate-5001A and 5005FA2 boards
connected to the FortiSwitch-5003A interfaces in the trunk.

For information about FortiSwitch-5003A link aggregation for FortiGate-5140 chassis, see

“Fabric

channel layer-2 link aggregation” on page 33

. For information about FortiSwitch-5003A link

aggregation for FortiGate-5050 chassis, see

“Fabric channel layer-2 link aggregation” on page 56

.

Syntax

config switch fabric-channel trunk

edit <trunk_name>

set

members <interface_names>

end

Example

This example shows how to add slot-6, slot-7, and slot-8 to a trunk named trunk_678. This

trunk can distribute sessions to FortiGate-5001A or 5005FA2 boards in chassis slots 6, 7, and 8.

config switch fabric-channel trunk

edit trunk_678

set members slot-6 slot-8 slot-7

end

Variables

Description

Default

edit <trunk_name>

Enter the name of a trunk to add or edit. This trunk name

appears in fabric channel interface lists.

members <interface_names> Enter the names of the FortiSwitch-5003A fabric channel

interfaces to add to the trunk. An interface can be added to only

one trunk. Separate each interface name with a space. You

can enter the interface names in any order.
To add or remove an interface from a trunk, retype the

complete list as required.
For the fabric channel <interface_names> can be:
• slot-2/1 used to connect the fabric channels of two

FortiSwitch-5003A boards installed in the same chassis.

• slot-3 FortiGate chassis slot 3.

• slot-4 FortiGate chassis slot 4.

• slot-5 FortiGate chassis slot 5.

• slot-6 FortiGate-5140 chassis slot 6.

• slot-7 FortiGate-5140 chassis slot 7.

• slot-8 FortiGate-5140 chassis slot 8.

• slot-9 FortiGate-5140 chassis slot 9.

• slot-10 FortiGate-5140 chassis slot 10.

• slot-11 FortiGate-5140 chassis slot 11.

• slot-12 FortiGate-5140 chassis slot 12.

• slot-13 FortiGate-5140 chassis slot 13.
• slot-14/f8 FortiGate-5140 chassis slot 14 or

FortiSwitch-5003A front panel slot 14/F8.

• f7 FortiSwitch-5003A front panel slot F7.
• f6 FortiSwitch-5003A front panel slot F6.
• f5 FortiSwitch-5003A front panel slot F5.
• f4 FortiSwitch-5003A front panel slot F4.
• f3 FortiSwitch-5003A front panel slot F3.
• f2 FortiSwitch-5003A front panel slot F2.
• f1 FortiSwitch-5003A front panel slot F1.

Advertising