config switch fabric-channel physical-port

edit "slot-6"

set heartbeat enable

next
edit "slot-8"

set heartbeat enable

next
edit "slot-10"

set heartbeat enable

end

This example shows how to bring down the slot-2/1 FortiSwitch-5003A interface. You may need to

bring this interface down to disable communication between fabric channel 1 and fabric channel 2.

config switch fabric-channel physical-port

edit slot-2/1

set status down

end