Technical Specifications

MR-HD100 Media Recorder
188

Environment

• Operating Temperature: 0-40° C (32° -104°F)
• Storage Temperature: -20-60° C (-4° -140°F)
• Ambient Operating Humidity: Within 10% to 85% (relative

humidity)

• Shock (Drop Test): Operating 50cm / Non-operating 100cm

Power

• Main unit:

11 – 18V DC,
Low power consumption. less than 3W during record,

• Removable and rechargeable Li-Ion battery pack:

Capable of more than 3 hours of continuous record operation,
Battery charger built into the unit,

• Supplied external AC adapter with restraining mechanism,
• Accept/receive power via USB 2.0 port:

Maximum 2.5W (500mA),
Operation Only - Does Not Charge Battery,

• Power From External DC Battery Devices

The ability to charge the MR-HD100 battery when operating

using an external DC battery device is dependent on the load

placed on the MR-HD100.
Consider the following when using external DC battery devices

to power the MR-HD100. The typical external DC video device

is 12V or 14.4V.

Power Consumption Tables

No Battery Installed - no charging current

Volt- in

No Dongle

With Linksys Dongle

Notes

14.4 V

0.238A (3.42W)

0.328A (4.72W)

idle-LCD/Backlight at
max

12.0V

0.285A (3.42W)

0.398A (4.77W)

idle-LCD/Backlight at
max