15 setting data 4 to data output – Furuno GP-90 User Manual
Page 17
5. INITIAL SETTINGS
15
Setting DATA 4 to Data Output
1) Press [MENU], [9] and [5]. The DATA 4 I/O SETUP menu appears.
DATA 4 I/O SETUP 1/2
To Next Page
ENT : Enter
MENU : Escape
Appears only when external
DGPS receiver is used.
DATA 4. Level
RS232C
RS422
Data
Out
Com. DGPS
: Select
Figure 5-5 DATA 4 I/O SETUP menu
2) Press
S
or
T
to select DATA4. Level.
3) Press
W
or
X
to select level of external equipment; RS232C or RS422.
4) Press the [ENT] key.
5) Press
W
or
X
to select Out.
6) Press
T
to select to Next Page. The DATA 4 I/O SETUP <out> menu appears.
To Previous Page
Talker ID
GP
LC
DE
Output Data (00-90 sec) 100%
DATA 4 I/O SETUP <Out> 2/2
MENU : Escape
ENT : Enter
Data Fmt.
V1.5
V2.0
IEC
1. AAM:00 APA:00
APB:04
BOD:00
2. BWR:00 BWW:00 GGA:00 GLL:01
3. RMB:01 RMC:00 VTG:01
WCV:00
4. VDR:00 WPL:00
XTE:00
ZDA:01
5. GNS:00 GBS:01
Rnn:00
RTE:00
Figure 5-6 DATA 4 I/O SETUP <out> menu
7) Follow "DATA 1 output setting" from step 2.