1. Turn on the GP-90.
2. Confirm that "OK" and "BEACON RCVR INSTALLED" are displayed on the self-test

display.

Confirm that "BEACON RCVR
INSTALLED" is displayed when
DGPS function is provided.

BEACON RCVR INSTALLED
DATA 3: DATA OUTPUT

PROGRAM MEMORY

=OK

SRAM

=OK
=OK

Internal Battery

Self-test display at equipment start up


3. Press [MENU ESC], [8] and [1]. Confirm that "BEACON OK" is displayed.

DGPS Setup

The default setting is "manual".

Automatic DGPS setup

The beacon receiver (GR-7000A) can automatically select optimum reference station by
feeding GP-90’s position data. If it takes more than 5 minutes to fix DGPS position at the
automatic mode, switch to manual mode. Use the manual mode when an external beacon
receiver has no automatic function of station selection.

1. Press [MENU ESC], [9] and [7] to display the DGPS SETUP menu.

These items appear when
"Man" is selected.

WAAS/DGPS SETUP

Freq.

288.0kHz

ENT: Enter

MENU: Escape

Baud Rate

200 bps

MODE

WAAS SEARCH

Auto

Man (GEO= )

___

:Select

GPS

CORRECTIONS DATA SET 00

DGPS Station

Auto

___

(ID= )

Man

Figure 5-1 DGPS SETUP menu


2. Press

S

or

T

to select DGPS MODE and press

W

to select “INT BEACON”.

3. Press

S

or

T

to select DGPS Station.

4. Press

W

to select Auto.