Installation – FMI COMFORT FLAME CDCFPRB User Manual
Page 11
www.fmiproducts.com
124979-01C
11
iNsTallaTioN
Continued
3. Install gas piping to fireplace location. This
installation includes an approved flexible
gas line (if allowed by local codes) after
the equipment shutoff valve. The flexible
gas line must be the last item installed on
the gas piping.
4. If you have not installed hood, follow
instructions on page 6.
5. Carefully set fireplace in front of rough
opening with back of fireplace inside wall
opening.
6. Attach flexible gas line to fireplace gas
regulator. See Connecting Equipment
Shutoff Valve to Heater Control, page 14.
7. Bend four nailing flanges on outer casing
with pliers (see Figure 10).
8. Attach fireplace to wall studs using nails
or wood screws through holes in nailing
flange.
9. Check all gas connections for leaks. See
Checking Gas Connections, page 14.
10. If using optional trim kit, install the trim
after final finishing and/or painting of wall.
See instructions included with trim acces-
sory for attaching trim.
IMPORTANT: When finishing your firebox,
combustible materials such as wall board,
gypsum board, sheet rock, drywall, plywood,
etc. may be butted up next to the sides and
top edge of the firebox. Combustible materi-
als should never overlap the firebox front
facing.
Figure 9 - Rough Opening for Installing
in Corner
Figure 8 - Rough Opening for Installing
in Wall
43
5
/
16
"
30
5
/
8
"
61
1
/
4
"
26
7
/
8
"
Figure 10 - Attaching Fireplace to Wall
Studs
Nailing
Flanges
Nails or
Wood
Screws
Wall Studs
2. If installing GA3450TA blower accessory,
do so at this time. Follow instructions
included with blower accessory.
Note: If not installing blower accessory,
you may wish to run electrical wiring to
your fireplace for future blower installation
(see Accessories, page 31). Use only ap-
proved three-wire electrical wiring.
WARNING: If pre-wiring, do
not connect wiring to any electri-
cal source at this time.
Install fireplace electrical outlet
and connect wiring to outlet
before connecting to electrical
source. The fireplace electri-
cal outlet is included with the
GA3450TA blower accessory.
Only use the fireplace electrical
outlet supplied with the GA3450-
TA blower accessory.
Note: A qualified installer should make all
electrical connections.
26
7
/
8
"
26
7
/
8
"
3/4" Off
The Floor
Minimum
15
1
/
4
"