Customising the Control Unit

29

Use the

A and V keys to change the sensitivity.

For example, the display will show:

12dB

Switch between the source you are changing and the

reference source until they sound equally loud.

Repeat the procedure for your other sources.

When you have finished programming levels, switch the

power off and on again to restore the control unit to normal

operation.

If you know the output level of your sources you can probably

set the gains by calculation. The following table shows the

correspondence between the gain and sensitivity on the

standard audio inputs and on the LP inputs:

Gain

A2-A6

LP MM

LP MC

0dB

150mV

3mV

210

µ

V

3dB

110mV

2.2mV

150

µ

V

6dB

75mV

1.5mV

110

µ

V

9dB

54mV

1.1mV

75

µ

V

12dB

38mV

750

µ

V

54

µ

V

15dB

27mV

550

µ

V

38

µ

V