Safety Measures

The instruments FLUKE T100/T120/T140 have

been constructed and verified in compliance

with the safety measures for voltage testers

and have left the factory in safe and perfect

condition.

In order to avoid electrical shock, the valid

safety and VDE regulations regarding ex-

cessive contact voltages must receive ut-

most attention, when working with volta-

ges exceeding 75V (60V) DC or 50V

(25V)rms AC. The values in brackets are

valid for spezial ranges (for example medi-

cine and agriculture).

The detector shall not be used, if the bat-

tery box is open.

Prior to each test, ensure the proper con-

dition of the measuring line and the mea-

suring instrument, e.g. broken cables or

leaking batteries.

Prior to measurement ensure that the test

leads and the test instrument are in per-

fect condition.

When using this instrument only the hand-

les of the probes may be touched .

This instrument may only be used within

the ranges specified (see 6.0 Technical

Data) and within voltage systems up to

690V

The measuring instrument may be used only in

the measuring circuit category it has been de-

signed for!

Instrument's faultless functionality must be veri-

fied prior to every use.

1) Short-circuit the probes. The Rx/Ohm LED

must light up. If not, remove/replace the

batteries.

2) Test the voltage tester on a known voltage

source.

Prior to usage ensure perfect instrument

function (e.g. on known voltage source).

The voltage testers may no longer be used

if one or several functions fail or if no

functionalityis indicated.

Fluke T100/120/140
Safety Measures

4