Downloading data and erasing memory – Fluke 1750 User Manual

Page 39

Advertising
background image

Power Recorder

Downloading Data and Erasing Memory

31

If the password is incorrect the password text field is cleared and then you can re-enter

the password.When the password is accepted, the Home screen appears.

Note

A screen to set up password protection for a Recorder is provided in the

1750 Setup menu.

Downloading Data and Erasing Memory

Use the Data menu options to manage the Recorder memory and download recorded data

to the SD card plugged into the Recorder's (not the PDA) SD card slot. You are

downloading recorded data from the flash memory to an SD card in the Recorder. When

you want to use that data, you must move the card to the PDA. You can later copy the

data to your PC for review using the Power Analyze software. Tap 1750 Internal

Memory in the Data menu to view the Download screen.

Azd116.bmp

The Download screen shows a three-phase rms V strip chart with date and timescale

shown. This represents the data in the Recorder internal memory. The default settings of

the start and stop times is everything in memory. To download ALL, tap the Write to SD

button. If you want to trim off data that contains partial information because probes were

being connected, select the START mark annotation (if one was entered by the user) as

the start point.
The gray cursor lines right and left with triangular arrowheads at the bottom of the screen

show the start and stop times currently selected for download. Green and red flags are

START and STOP mark annotations inserted during the recording session. Yellow flags

are file name annotations inserted during the recording session, or setup parameter

changes that change the data significantly, such as nominal voltage or power type.