Electronic control features – FRIGIDAIRE 297298700 User Manual

Page 9

Advertising
background image

9

ELECTRONIC CONTROL FEATURES

PRO-SELECT™ ELECTRONIC CONTROL

FEATURES

Replace Air Filter

When the “REPLACE AIR FILTER” LED is illuminated
yellow, the air fi lter needs to be replaced. The control
will signal for air fi lter replacement after 3600 hours
of refrigerator operation. After replacing the air fi lter,
reset the air fi lter timer by pressing the AIR FILTER key
for 3 seconds. The “REPLACE AIR FILTER” LED will be
illuminated green for three (3) seconds, confi rming a
timer reset.

Control Lock

To disable the keypads on the control, begin by pressing
the CONTROL LOCK key for three seconds until “LO” is
displayed for 1 second. With the control locked, when
keys are pressed on the control panel, “LO” will be
displayed. To unlock the control, press the CONTROL
LOCK key for three seconds. The display will show “UL”
for one second.

Power Fail

The POWER FAIL indicator light informs you that due
to a power failure, the cabinet temperature exceeded
55°F (13°C). If the power failure lasted more than one
(1) hour, the display alternates between showing the
power failure duration (Hours and DURATION LED
illuminate in the display) and the cabinet temperature
(°F or °C illuminates) every ½ second. This safety
feature will aid in determining what food spoilage action
to take.

°F

Door Ajar

Indicator

Power Fail Indicator

Adjust DOWN Key

Adjust UP Key

Control Lock Key

Replace Air Filter

Indicator

Air Filter Reset Key Temp Mode Key Alarm Reset Key

Electronic Control Panel Layout

°F

HRS

HI-TEMP DURATION

°F

Setting Control Lock

Power Fail Indicator

Resetting Air Filter Alarm