30" electric range installation instructions, Four conductor wire connection to range, Three conductor wire connection to range – FRIGIDAIRE 318201724 User Manual

Page 3

Advertising
background image

3

30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS

Four Conductor Wire Connection to Range

Where local codes does NOT permit connection of the frame
grounding conductor to the neutral wire of the copper power
supply cord (see Figure 4):

1. Remove the screws from the access plate at the lower right

end of the rear cover to expose range terminal connection
block.

2. Remove the grounding strap from the terminal block and

from the appliance frame.

3. Using the nuts supplied with the literature package,

connect the ground wire (green) of the copper power
supply cord to the frame of the appliance with the ground
screw, using the hole in the frame where the ground strap
was removed (see Figure 4).

4. Connect the neutral of the copper power supply cord to

the center silver-colored terminal of the terminal block,
and connect the other wires to the outer terminals. Match
wires and terminals by color (red wires connected to the
right terminal, black wires connected to the left terminal).

5. Replace the terminal cover and replace the screws.

Terminal Block

Silver Colored Terminal

Red

Wire

Neutral

(White Wire)

Ground (Bare

Copper Wire)

To 240 V Receptacle

A User Supplied

Strain-relief Must

Be Installed at This

Location

Black Wire

1 1/8" (2.9cm)

Dia. Direct

Connection

Hole. Punch

Out Knockout

for 1 3/8"

(3.5cm) Dia.

Cord Kit Hole.

NOTE: Be sure to remove the

supplied grounding strap.

Figure 4

Three Conductor Wire Connection to Range

If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power supply cord
(see Figure 3):

1. Remove the screws from the access plate at the lower right

end of the rear cover to expose range terminal connection
block.

2. Using the nuts supplied in the literature package, connect

the neutral of the copper power supply cord to the center
silver-colored terminal of the terminal block, and connect
the other wires to the outer terminals. Match wires and
terminals by color (red wires connected to the right
terminal, black wires connected to the left terminal) (see
figure 3).

3. Replace the terminal cover and replace the screws.

Figure 3

Silver Colored Terminal

1 1/8" (2.9 cm) Dia.

Direct Connection

Hole. Punch Out

Knockout for 1 3/8"

(3.5 cm) Dia. Cord

Kit Hole.

To 240 V

Receptacle

A User Supplied

Strain-relief Must

Be Installed at This

Location.

Black

Wire

Terminal

Block

Cord

Mounting

Plate

Neutral

(White Wire)

Grounding

Strap

Red Wire

Advertising