The dryer is equipped with a three-prong (grounding) plug

1.

for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong
receptacle.

The plug must be plugged into an appropriate outlet that

2.

is properly installed and grounded in accordance with all
local codes and ordinances. If in doubt, call a licensed
electrician.

DO NOT cut or remove ground prong from the plug.

Grounding type

Grounding type
wa

wall receptacl

ll receptacle

Po

Power cord with

wer cord with

3-prong

3-prong gr

grounded plug

ounded plug

Do not,

Do not, under

under

an

any cir

y circumstances,

cumstances,

cut,

cut, remo

remove

ve,

or b

or bypass th

ypass the

gr

grounding pr

ounding prong.

ong.

Grounding requirements - Gas dryer (USA and Canada)

Gas connection

Remove the shipping cap from gas pipe at the rear of the

1.

dryer.

Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved

2.

pipe from gas supply line to the 3/8 inch (0.96 cm) pipe
located on the back of the dryer. Use a 1/2 inch to 3/8
inch (1.27 cm to 0.96 cm) reducer for the connection.
Apply an approved thread sealer that is resistant to the
corrosive action of liquefi ed gases on all pipe connections.

Open the shutoff valve in the gas supply line to allow gas

3.

to fl ow through the pipe. Wait a few minutes for gas to
move through the gas line.

All connections must be wrench-tightened

Flare

Union

Flare

Union

GAS FLOW

Manual

Shutoff

Valve

Closed

Open

Flexible

Connector

Inlet Pipe on

Back of Dryer

e

l

p

p

i

N

Shutoff Valve -

Open position

to dr

yer

from gas supply

Check for gas system leaks with a manometer. If a

4.

manometer is not available, test all connections by
brushing on a soapy water solution.

10

- EXPLOSION HAZARD - NEVER test for gas

leaks with an open fl ame.

The supply line must be equipped with an ap-

proved manual shutoff valve. This valve should be located in
the same room as the dryer and should be in a location that
allows ease of opening and closing. Do not block access to
the gas shutoff valve.

DO NOT connect the dryer to L.P. gas service

without converting the gas valve. An L.P. conversion kit must
be installed by a qualifi ed gas technician.