Electrical connection (non-canada) - 3 wire cord, Wire receptacle (nema type 10-30r) – FRIGIDAIRE 137111500B User Manual

Page 11

Advertising
background image

11

Electrical connection (non-Canada) - 3 wire cord

Turn off power supply to outlet.

1.

Remove the screw securing the terminal block access

2.

cover in the lower corner on the back of the dryer.

Install a UL-approved strain relief according to the power

3.

cord/strain relief manufacturer’s instructions in the power
cord entry hole below the access panel. At this time, the
strain relief should be loosely in place.

Thread an UNPLUGGED, UL-approved, 30 amp. power

4.

cord, NEMA 10-30 type SRDT, through the strain relief.

Attach the power cord neutral (center wire) conductor to

5.

the SILVER colored center terminal on the terminal block.
Tighten the screw securely.

Attach the remaining two power cord outer conductors

6.

to the outer, BRASS colored terminals on the terminal
block. Tighten both screws securely.

3-wire receptacle

(NEMA type 10-30R)

Internal ground

Internal ground

(GREEN screw)

(GREEN screw)

Install

Install

UL-approved

UL-approved

strain relief here

strain relief here

Terminal screw

Terminal screw

recovery slot

recovery slot

Line 1

Line 1

(BRASS terminal)

(BRASS terminal)

Neutral

Neutral

(SILVER terminal)

(SILVER terminal)

Line 2

Line 2

(BRASS terminal)

(BRASS terminal)

Access cover

Access cover

screw

screw

Terminal

Terminal

block

block

Neutral

Neutral

(center wire)

(center wire)

30 AMP

30 AMP

NEMA 10-30

NEMA 10-30

Follow manufacturer’s guidelines for fi rmly securing the

7.

strain relief and power cord.

Reinstall the terminal block cover.

8.

DO NOT remove

DO NOT remove

internal ground in

internal ground in

a 3-wire system!!

a 3-wire system!!

Neutral

Neutral

terminal

terminal

- ELECTRICAL SHOCK HAZARD - Failure

to disconnect power source before servicing could result in
personal injury or even death.

- ELECTRICAL SHOCK HAZARD - Do not

make a sharp bend or crimp wiring/conductor at connections.

If moving dryer from a 4-wire system and

installing it in a 3-wire system, move the internal ground from
the center terminal back to the GREEN screw next to the
terminal block.

If a terminal screw falls during cord installation, it

can be retrieved in the terminal screw recovery slot below the
access panel.