Foster Induction Hobs 7322 240 User Manual

Page 7

Advertising
background image

20

Start-up/ switch off the heating zone :

Action

Control panel

Display

Increase power

Press key [ + ]

[ 4 ] to [ 9 ]

Decrease power

Press key [ - ]

[ 9 ] to [ 1 ]

Stop

Press simultaneous[ + ] and [ - ] [ 0 ] or [ H ]

or press [ - ]

[ 0 ] or [ H ]

If no setting are made in 20 seconds the hob return in waiting position.

Pan detection

The pan detection ensures a perfect safety.

The induction doesn’t work:

If there is no pan on the heating zone or if this pan is not adapted to the induction. In this

case it is impossible to increase the power and the display shows [ U ]. This symbol

disappears when a pan is put on the heating zone.

If the pan is removed from the heating zone the operation is stopped. The display shows

[ U ]. The symbol [ U ] disappears when the pan is put back to the heating zone. The

cooking continues with the power level chosen before.

Residual heat indication

After the switch-off of the hob, the heating zone is still hot and indicates [ H ] on the display.

The symbol [ H ] disappears when the heating zone may be touched without danger.

As far as the residual heat indicator is on light, don’t touch the heating zone and don’t put any

heat sensitive object on them. There are risks of burn and fire.

Booster function

The booster function [ P ] grants a boost of power to the selected heating zone.

If this function is activated the heating zones works during 10 minutes with an ultra high power.

The booster is foreseen for example to heat up rapidely big quantities of water, like nuddles

cooking.

Start up / Stop the booster function :

Action

Control panel

Display

Increase power

Press key [ + ] or [ - ]

[ 1 ] to [ 9 ]

Start up the booster

Press key [ + ]

[ P ] during 10 min.

Stop the booster

Press key [ - ]

[ 9 ]

Power management :

The whole cooking hob is equipped by a maximum of power. When the booster function

isactivated, and not to exceed the maximum power, the electronic system orders to reduce

automatically the power level of an other heating zone. The display is blinking on [ 9 ] during a

few seconds and then shows the maximum of power allowed ( [ 6 ] or [ 8 ] ).

Heating zone selected

The other heating zone: (example: power level 9)

[ P ] is displayed

[ 9 ] goes to [ 7 ] or [ 8 ] depending the type of zone


Advertising
This manual is related to the following products: