24

ELECTRICAL CONNECTION

The installation of this appliance and the connection to the electrical network should be

entrusted only to an electrician perfectly to the fact of the normative regulations and

which respects them scrupulously.

Protection against the parts under tension must be ensured after the building-in.

The data of connection necessary are on the stickers place on the hob casing near the

connection box.

The connection to the main must be made using an earthed plug or via an omnipolar

circuit breaking device with a contact opening of at least 3 mm.

The electrical circuit must be separated from the network by adapted devices, for

example: circuit breakers, fuses or contactors.

Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz

Connect always the earth wire.

Respect the connection diagram.

Use the connecting cable that is attached to the device.

The green / yellow wire correspond to the earth wire, the blue wire correspond neutral wire and

the brown wire correspond to the phase.

Mains

Connection

Cable diameter

Cable

Protection calibre

230V~ 50/60Hz

1 Ph. + N

3 x 2,5 mm²

H 05 VV - F

H 05 RR - F

16 A *

(*) calculated with the simultaneous factor following standard EN 60 335-2-6/1990

Caution! Ensure that you correctly attach the wires and the bridges and tighten the
screws properly.

We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been