7-13

7.10 Interface Board Diagnostic Chart

The following diagram and charts provide ten quick system checks that can be performed using only
a multimeter.





















Meter Setting

Test

Pin

Pin

Results

12 VAC Power

50 VAC Scale

3 of J2

1 of J2

12-16 VAC

24 VAC Power

50 VAC Scale

2 of J2

Chassis 24-30 VAC

*Probe Resistance (RH)

R X 1000 OHMS

11 of J2

10 of J2 See Chart

*Probe Resistance (LH)

R X 1000 OHMS

1 of J1

2 of J1

See Chart

High-Limit Continuity (RH)

R X 1 OHMS

9 of J2

6 of J2

0 - OHMS

High-Limit Continuity (LH)

R X 1 OHMS

6 of J1

9 of J1

0 - OHMS

Latch Contactor Coil (RH)

R X 1 OHMS

8 of J2

Chassis 3-10 OHMS

Latch Contactor Coil (LH)

R X 1 OHMS

5 of J1

Chassis 3-10 OHMS

Heat Contactor Coil (RH)

R X 1 OHMS

7 of J2

Chassis 18-25 OHMS

Heat Contactor Coil (LH)

R X 1 OHMS

4 of J1

Chassis 18-25 OHMS

* Disconnect 15-Pin harness from the computer/controller before testing the probe circuit.

Diagnostic LED Legend

CMP indicates power from 12V transformer
24

indicates power from 24V transformer

HI

(RH) indicates output (closed) from right
latch relay

HI

(LH) indicates output (closed) from left
latch relay

HT

(RH) indicates output from right heat
relay

HT

(LH) indicates output from left heat relay

AL

(RH) indicates output (open) from right
latch relay

AL

(LH) indicates output (open) from left
latch relay

3

2

1

6

5

4

9

8

7

12

11

10

3

2

1

6

5

4

9

8

7

12

11

10

K1

K2

K3

K4

Left

Latch

Relay

Right

Latch

Relay

Left

Heat

Relay

Right

Heat

Relay

1

2

3

4

5

6

8

7

9

10

11

12

13

14

15

J3

J1

J2

AL HI HTCMP24V HT HI AL

Diagostic LEDs

Test Points

J1 Left J2 Right

NOTE – When testing the test points on J1
and J2 test use the illustration above dis-
regarding any silkscreened numbers on
the board depicting the location of Pin 1.
Pin 1 is located in the bottom right corner of
Both J1 and J2. These test points are ONLY
for RE Series boards with J1 and J2 plugs on
the front of the board.

PN 106-6811