5.7.4.3 STATISTICS SETTINGS (F3)

MAIN MENU | DISPLAY MENU |

The Statistics Settings screen allows the user to set statistics related settings such as the statistics mode to be

used.
STATISTICS MODE – determines the mode in which statistics are used. The options are LIMITED and

UNLIMITED.
In Limited mode, statistics are calculated using a sliding window that is limited in width by the number of

samples defined in the Sample Count setting. The oldest measurement leaves the sliding window buffer when

a new measurement enters.
Unlimited mode allows the number of samples to grow indefinitely until the user resets the statistics or stops

measurement.
SAMPLE COUNT - defines the number of samples on which the statistics are based. In LIMITED mode, this

setting defines the width of the sliding window. A maximum of 100 can be selected.
DELTA MODE - determines whether the Delta statistics field is based on a measurement from a channel or an

offset entered by the user. The options are CHANNEL or OFFSET.
DELTA OFFSET - sets the offset value used for calculating Delta. This setting applies when Delta Mode is

set to OFFSET.
When the Delta Offset value is subtracted from a measurement, it assumes the same units as the measurement.

The setting has a range of -1.0E06 to 1.0E06.

Tip:

Delta Mode is useful for automatically subtracting an offset from a measurement such as the lead

resistance offset used when making 3-wire measurements.

DELTA CHANNEL- specifies the channel to be used as the reference for the Delta calculation. This setting is

applicable when Delta Mode is set to CHANNEL. Possible options are channels 1 through 4 when no scanner

is attached. If a scanner is attached, channel 1 is not available but the scanner channels are.

5.7.4.4 GRAPH SETTINGS (F4)

MAIN MENU | DISPLAY MENU |

The Graph Settings function key opens a screen that contains settings for controlling how data graphs appear

in the Measurement Screen in Show Graph mode. The configuration fields in the Graph Settings screen are as

follows:
COMBINED GRAPH - determines if all enabled channels are plotted on the same graph or on separate

graphs. ON plots all channels on the same graph.
TIME SPAN - configures the horizontal time scale or width of the graph window. The options are 5 min, 10

min, 15 min, 30 min, 1 hr, 2 hr, 4 hr, and 8 hr. The default is 10 min.
AUTOMATIC CENTERING - determines whether the center of the vertical axis is set automatically based

on the data in the graph (ON) or if the center is fixed at the Vertical Center value (OFF). The default value is

ON.
VERTICAL CENTER - sets the center of the vertical axis of the combined graph when Automatic Centering

is ON. The setting has a range of -1.0E6 to 1.0E6. The default value is 0.0.
AUTOMATIC SCALING - determines whether the scale of the vertical axis is set automatically based on the

data in the graph (ON) or if the scale is fixed at the Vertical Scale value (OFF). The default value is ON.
VERTICAL SPAN - sets the scale of the vertical axis of the combined graph when Automatic Scaling is OFF.

The setting has a range of 1.0E-6 to 1.0E6. The default value is 0.1.