Appliance start-up, Features – FRIGIDAIRE Artic Air Commerical Glass Door Refrigerator User Manual

Page 4

Advertising
background image

5

Appliance Placement

Leave a three (3) inch space on all sides and the back
of the cabinet for adequate air circulation. Choose a
place that is near a grounded electrical outlet. For the
most efficient operation, the appliance should be
located where surrounding temperatures will not
exceed 100°F (38°C). Appliance should not be
operated in ambient below 32°F (0°C). Additional
compressor heaters are not recommended.

Insulation

The insulated space of this cabinet is sealed to
maintain peak efficiency. Holes drilled in the cabinet
may destroy that seal and damage electrical wiring
located in the insulated space.

DAMAGED ELECTRICAL WIRING OR WET
INSULATION CAUSED BY DRILLING WILL VOID THE
WARRANTY.

Appliance Start-Up

Once the appliance has been located in its permanent
location and the proper power and grounding has
been provided, the following items must be checked or
completed:

Cool Down Period

For safe food storage, allow 24 hours for the appliance
to cool down completely before loading with food.
The appliance will run continuously for the first several
hours. Do not place any food in the appliance until
after the first 24 hours of operation.

Thermostat Settings

The appliance is shipped from the factory with the
thermostat set at about the mid-point of the operating
range. Adjustments colder or warmer can be made
after the appliance has been running for at least 8
hours. Allow at least 8 hours for temperature
stabilization before re-adjusting the thermostat.

Defrost Setting

The appliance is designed to defrost automatically
every 12 hours. To set the time of defrost, wait until
the desired time to defrost. With the notch on the
timer knob aligned with the line on the bracket
(Figure A), turn the defrost timer knob clockwise
slowly. The timer will click several times, then once
loudly, at which point the defrost cycle begins. The
timer knob will advance through the defrost cycle,
then click loudly at the end of the cycle (Figure B).
The appliance will defrost automatically every 12 hours
after the first defrost cycle.

For example, to set the appliance to defrost at 10:00
a.m., turn the timer knob clockwise at 10:00 a.m. until
the timer clicks loudly.The appliance will defrost daily
at 10:00 a.m. and again12 hours later at 10:00 p.m.
Note: The product interior temperature will rise during
the defrost cycle every 12 hours.

Defrost Timer

Back of Unit

The appliance is provided with 4 shelves. One goes on
the floor of the cabinet and the other 3 are placed in
the metal side supports wherever they are needed. The
shallow shelf goes in the upper position.

Features

• Heavy duty epoxy powder coated adjustable shelving
• NSF certified top mounted evaporator
• 2-1/2" urethane foam cabinet insulation
• Torsion spring door closer
• Heavy duty swivel casters
• 17 watt fluorescent lamp
• Removable stainless steel drain cover
• Adjustable temperature control
• NSF certified interior
• Stainless steel evaporator housing
• Stainless steel toe plate
• Heavy duty commercially rated electrical harness
• Heavy duty removable stainless steel shelf supports

Shelves

Figure A

Position of knob

before turning clockwise

to start defrost cycle.

Figure B

Position of knob

at end of defrost cycle.

Advertising