Turning off fortigate-4000 chassis power, Hot swapping modules – Fortinet FortiGate 4000 User Manual

Page 41

Advertising
background image

Getting started

Hot swapping modules

FortiGate-4000 Installation and Configuration Guide

41

2

Connect the three power cables to the power connection module on the
FortiGate-4000 chassis back panel.

3

Connect the power cables to power outlets.

4

Turn on the power switch on each power supply module.

5

Press and hold the chassis power switch for a few seconds to turn it on to supply
power to the power supplies.
The Power LED on each power supply module lights.

6

Turn on the management module power switch.

7

Turn on the switched interface module power switch for each switched interface
module (FortiGate-4000S).

8

Press and hold the power button on each FortiBlade-4010 module for a few seconds.
The PWR LED on each FortiBlade-4010 module lights.

Turning off FortiGate-4000 chassis power

Turning off the FortiGate-4000 chassis power in the reverse order from turning power
on.

1

Press the power button on each FortiBlade-4010 module.
The PWR LED on each FortiBlade-4010 module goes out.

2

Turn off the switched interface module power switch for each switched interface
module (FortiGate-4000S).

3

Turn off the management module power switch.

4

Turn off the chassis power switch.

5

Turn off the power switch on each power supply module.

Hot swapping modules

This section describes how to hot swap the modules installed in the FortiGate-4000
chassis. Hot swapping refers to removing a failed module and replacing it with a new
version of the same module while the FortiGate-4000 chassis remains in operation.

This section describes:

Hot swapping FortiBlade-4010 modules

Hot swapping cooling fan trays

Hot swapping power supplies

Hot swapping interface modules

Hot swapping the 10/100 out of band management module

Hot swapping the management module

Hot swapping the KVM switch module

Note: Always wait at least five seconds after turning off FortiGate-4000 chassis power before
turning it back on. Turning the power on and off in rapid succession can damage
FortiGate-4000 electrical circuitry.

Advertising