14. Reinstall and secure the fryer control panel. Loosen the temperature dial plate screws and rotate

the dial until the 325°F (162°C) index mark is at the 12 o’clock position, then retighten the
screws.


15. Reinstall the thermostat knob with its pointer aligned with the 325°F (162°C) index mark on the

temperature dial plate. Tighten the thermostat knob set screws to prevent slippage.


2.5

Converting to Another Gas Type

"47" Series fryers are configured at the factory for either natural gas or Propane (LP) gas. A gas
conversion kit must be installed by a Factory Authorized Service Center technician when converting
from one type of gas to another.

DANGER

This appliance was configured at the factory for a specific type of gas. Converting
from one type of gas to another requires the installation of specific gas-conversion
components. Switching to a different type of gas without installing the proper
conversion components may result in fire or explosion. NEVER ATTACH THIS
APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED! Conversion
of this appliance from one type of gas to another should only be performed by
qualified, licensed, and authorized installation or service personnel, as defined in
Section 1.7 of this manual.

CE Gas Conversion Kits

Full-Vat

Natural to LP: 826-1462 (includes .86mm orifice, P/N 810-0340)

LP to Natural: 826-1463 (includes 1.40mm orifice, P/N 810-0330)

Dual-Vat

Natural to LP: 826-1464 (includes .80mm orifice, P/N 810-1040)

LP to Natural: 826-1465 (includes 1.30mm orifice, P/N 810-0131)

Non-CE Gas Conversion Kits

Robertshaw Gas Valves

Natural to LP: 826-0962 [for dual-vat configurations, order P/N 817-0098 (Qty-1) and P/N 810-
0148 (Qty-1) in addition to the kit]

LP to Natural: 826-0963 [for dual-vat configurations, order P/N 810-0187 (Qty-1) and P/N 810-
0149 (Qty-1) in addition to the kit]

Honeywell Gas Valves

Natural to LP: 826-1143 [for dual-vat configurations, order P/N 807-1846 (Qty-1) and P/N 810-
0148 (Qty-1) in addition to the kit]
LP to Natural: 826-1144 [for dual-vat configurations, order P/N 807-1849 (Qty-1) and P/N 810-
0149 (Qty-1) in addition to the kit]