23

REMEDY FOR THE INTERFERENCE TO
A VHF RADIOTELEPHONE

If a VHF radiotelephone is interfered by signal from the data cable between GPS receiver
and the GR-80, follow the procedure shown below.

Procedure

1. The screen of the data cable is grounded effectively.

GR-80 DATA Connector

DATA Cable

Shield

Signal Cable

The shield must be grounded
through the cable clamp

GR-80 DATA Connector

DATA Cable

Solder the shield
to pin No.7.

Two Cables

The shield must be grounded
through the cable clamp.

Wind copper tape or mesh tape around
the cable before clamping.