5 receiving data from personal computer – Furuno DUAL GPS GP-150-DUAL User Manual

Page 60

Advertising
background image

8. MENU SETTINGS

8-8

To Previous Page

Talker ID GP LC DE
Output Data (00-90 sec) 100%

DATA 4 I/O SETUP <Out> 2/2

MENU : Escape

ENT : Enter

Data FMT

V1.5 V2.0

IEC

1. AAM:00 APA:00 APB:04 BOD:00
2. BWR:00 BWW:00 GGA:00 GLL:01
3. RMB:01 RMC:00 VTG:01 WCV:00
4. WNR:00 WPL:00 XTE:00 ZDA:01
5. GNS:00 GBS:01 Rnn:00 RTE:00

Figure 8-10 DATA 4 I/O SETUP menu (2/2)


7) Follow "DATA 1 output setting" from step

2.


8.5 Receiving

Data

from

Personal Computer

Loading waypoint/route data

Waypoints and routes data can be
downloaded from a personal computer,
through the DATA 4 connector.

1) Press MENU ESC, 9 and 5.
2) Press to select DATA 4 Level.
3) Press or to select level of personal

computer; RS232C or RS422.

4) Press the NU/CU ENT key.
5) Press or to select COM.
6) Press to select To Next Page. The

DATA 4 I/O SETUP menu appears.

To Previous Page
Baud Rate 9600 bps

Command Stop Start

Save Data WPT/ROUTE

Command Stop Start

DATA 4 I/O SETUP <COM> 2/2

MENU : Escape

ENT : Enter

: Select

Load Data

WPT/ROUTE

WPT

Figure 8-11 DATA 4 I/O SETUP menu (2/2)

7) Press to select Baud Rate.
8) Press or to select baud rate; 4800

bps, 9600 bps, or 19200 bps.

9) Press the NU/CU ENT key.
10) Press

or to select WPT/RTE.

11) Press

to select Command. Stop, on

the same line as Command, appears in
reverse video.

12) Press

to select Start. The message

shown in Figure 8-12 appears.

Loading erases current data
and stops Route navigation
Are you sure to load ?
ENT: Yes MENU:No

Figure 8-12


13) Press the NU/CU ENT key. The message

shown in Figure 8-13 appears.

Now loading
Waypoint/Route data !

MENU:Stop

Figure 8-13


14) Operate the computer to output data.

When data is loaded, the cursor shifts to
Stop.

15) Press the MENU ESC key. When data is

loaded successfully, The message shown
in Figure 8-14 appears.

Loading ended successfully

Press any key

Figure 8-14

If data could not be loaded, the message
shown in Figure 8-15 appears.

Failed in loading

Invalid data

Press any key

Figure 8-15

Advertising