Frymaster 45 Series User Manual

Page 36

Advertising
background image

1-30

1.10.2 Troubleshooting the 24 VAC Circuit in Units with Interface Boards

Verify that the drain

valve is fully closed, then

turn the controller on.

Which LEDs are lit?

24V LED only

None

GV LED (with

or without

other LEDs)

Is 24VAC

present on IFB 24V

terminals?

Probable cause

is a failed 24-volt

transformer.

No

Is 24VAC

present on J1

Pin 6?

Yes

Probable cause

is a failed interface

board.

No

Is pilot lit?

Is 24VAC

present on Pin 20 of 20-pin

terminal block?

Is 24VAC

present at the gas

valve?

Yes

Yes

Yes

Attempt to light pilot. If

the pilot will not light, see

Troubleshooting the Gas

Valve on Page 1-33.

No

If unit has a drain safety switch,

probable cause is open or failed

switch. If not, probable cause is loose

or missing jumper between Pins 10

and 19 of 20-pin terminal block.

No

Probable cause is failed

wiring between 20-pin

terminal block and gas

valve.

No

Problem is with gas valve.

See Troubleshooting the

Gas Valve on Page 1-33.

Yes