Wiring, Power cable, Display unit, rear view – Furuno GP-1650W User Manual

Page 12: Connecting the power cable to the battery

Advertising
background image

4

2. WIRING

All wiring are terminated at the rear of the display unit.

Antenna unit

GPA-017
(GP-1650W)

Earth terminal

DGPS beacon receiver
(option for GP-1650W,
RS-232C only)

External
equipment

Black

White

Shield

Displa unit

GPA-019
(GP-1650WD)

ANT

XDR

DGPS

NMEA

13GND

2

12-24

VDC

-

+

Display unit, rear view

Power cable

Connect the power cable to the power connector. Connect the leads to the battery (12 or 24
VDC); white to plus(+) terminal and black to minus(-) terminal.

Cable connector

Power cable
w/fuse (3A)

Lead wire

White

Black

BATTERY

Connecting the power cable to the battery

Advertising