MB15C02

(b) Charge pump

The charge pump is available in two forms: internal external.

Internal charge pump output (Do)
External charge pump outputs (

φ

R,

φ

P)

(c) Phase comparator input/output waveforms

The phase comparator outputs logic levels summarized in Table 1, according to the phase error between fr
and fp. Note that

φ

P is an Nch open drain output. The pulse width of the phase comparator outputs are identical

and equal to the phase error between fr and fp as shown in Figure 1.

Figure 1. Phase comparator input/output waveform

fp

fr

When FC = “L”

When FC = “H”

Do

Do

High Z

High Z

φ

R

φ

P

φ

R

φ

P

High Z

High Z

High Z : High impedance state

fp

: Nch open output

Advertising