15

MB15C02

Since the divide rations are unpredictable when the MB15C02 is turned on, it is necessary to initialize the divide
ratio for both dividers at power-on time. As shown in Figure 6, after setting the divide ratio for one of the dividers
(e.g., programmable reference divider), set LE to “H” level before setting the divide ratio for the other dividers (e.g.,
programmable divider). To change the divide ratio of one of the divider after initialization, input the serial data only
for that divider (the divide ratio for the other divider is preserved).

Figure 6. Inputting serial data(Setting divisors)

Data

Clock

LE

Serial data for program-
mable reference divider

1*

0*

Serial data for program-
mable divider

15 clocks

19 clocks

* : Control bit