11

307932

Installation

5.

Screw the 3/4 npt street elbow (28*) into the
pump’s fluid outlet. Assemble the nipple (27*),
check valve (29*), coupling (30*), and swivel (50*)
as shown in Fig. 6. The arrow on the check valve
must point down, toward the coupling.

6.

Screw an elbow (32*) onto the lower heater’s inlet.
Screw the coupler (63) onto the elbow. Attach the
heater hose (31*) to the coupler. Connect the other
end of the hose to the swivel (50*) coming from
the pump outlet.

7.

Screw an elbow (32*) onto the upper heater’s inlet.
Screw the coupler (63) onto the elbow. Attach the
second heater hose (31*) to the coupler. Run this
hose to the left of and behind the lower heater.
See Fig. 4.

8.

Install the bushing (62) and a 3/8 npt nipple (33*)
in the lower heater’s outlet. Screw the rigid end of
the union (34*) onto this nipple, and screw the
swivel end of the union onto the free end of the
second heater hose (31*).

9.

Screw the bushing (62) and a 3/8 npt nipple (33*)

into the upper heater’s outlet. Screw the fluid filter

(4) inlet onto this nipple. Unscrew the adapter (10)

from the filter outlet. Screw the 1/4 x 3/8 npt nipple

(35*) into the filter outlet, and screw the union (34*)

onto the nipple. See Fig. 6.

WARNING

COMPONENT RUPTURE HAZARD
To reduce the risk of overpressurizing
your system, which could cause compo-
nent rupture and serious injury, never

exceed 90 psi (6 bar, 600 kPa) incoming air pres-
sure to the pump
.

10. Install the warning label (51) as shown in Fig. 6.

4417B

2

1

3

9

10

4

11

24

Fig. 5

25