Installation, Warning – Graco Bulldog 245187 User Manual

Page 12

Advertising
background image

12 307932

Installation

Installing Circulating Kit 222312

WARNING

Before installing the heaters, dual heater mounting
kit and circulating kit, follow the Pressure Relief
Procedure
on page 14. Disconnect all hoses from
the pump.

NOTE: Reference numbers marked with a symbol (for
example, 37

{) are included in kit 222312.

Apply pipe sealant (36

{) to all male threads except at

swivel connections.

1.

Remove the suction tube (25), fittings (52 and 53),
hose (24), and adapter (12). See Fig. 5. Keep
these parts for use later.

2.

Screw nipple (54) and then the tee (48

{) into the

elbow (11) at the pump fluid inlet. Screw the 1 x
3/4 npt bushing (55) and then the 3/4 npt x 1/4 npt
bushing (49

{) into the branch of the tee. See Fig.

6.

3.

Reconnect the bushing (12), hose (24), fittings (52
and 53), and suction tube (25).

4.

Install the CIRC end of the three-way ball valve
(40

{) in the bushing (49{). Screw a bushing (39{)

onto the IN branch of the three-way valve. Con-
nect the rigid end of the 45

_ union (38{) to this

bushing. Screw the swivel end of the union (38

{)

onto the braided hose (37

{). Connect this hose to

the main fluid return line. See Fig. 6.

5.

Screw another bushing (39

{) onto the DRAIN end

of the three-way valve (40

{). Connect the nylon

fluid hose (41

{) to this bushing, and connect the

return tube (42

{) to the other end of the hose.

Place the return tube in the fluid supply container.

WARNING

COMPONENT RUPTURE HAZARD
To reduce the risk of overpressurizing
your system, which could cause compo-
nent rupture and serious injury, never

exceed 90 psi (6 bar, 600 kPa) incoming air pres-
sure to the pump
.

6.

Install the warning label (51) as shown in Fig. 6.

7.

Connect the air and fluid hoses and the spray gun
as explained on page 6.

Advertising