DUCTWORK, WIRING LOCATIONS

Determine the exact location of the insert
sleeve. Mark the exact centerline location.
The ceiling structure must be capable of
supporting the weight of the insert sleeve
(approximately 100 pounds), the canopy
itself, any mounting hardware and any
inadvertent user contact loads.

Measure from the top of the cooking

surface to the bottom edge of the insert
sleeve. Add insert sleeve installation height.
Mark that location.

Use a level to draw a straight horizontal

pencil line on the wall.

NOTE: House duct should drop to 11-1/2

above bottom edge of insert sleeve.
Location of house duct is important
because it must align with vent of
damper plate assembly.

Ceiling ducting:
If ductwork will vent straight up to the ceiling:

Use a level to draw a centerline straight up

to the ceiling.

On the ceiling, measure 5-1/2

from

the back wall to the centerline of an
8-1/2

hole.

Rear Wall Ducting: (See important note.)
If ductwork will vent to the rear:

Use a level to draw a centerline straight

up to the ceiling.

Measure at least 22-1/2

above the pencil

line that indicates the bottom installation
height, to the centerline of an 8-1/2

dia.

duct hole. (Hole may be elongated for duct
elbow.)

HOUSE WIRING LOCATION:

The junction box is located inside the top left

side of the hood.

Wiring should enter the back wall at least

15

above the bottom of the insert sleeve,

and within 6

of the left side of the

centerline.

22-1/2

above

pencil line
indicating
bottom of hood

5-1/2

from

rear wall to
centerline

*30

Minimum required

*36

Maximum recommended

installation height from
cooking surface

36

from

floor to
countertop

Wall Installation Preparation

*30

Minimum required

*36

Maximum recommended

installation height from
cooking surface

36

from

floor to
countertop

Front view

Side view

11-1/2

4

liner height

11-1/2

22-1/2

above

pencil line
indicating
bottom of hood

4

liner height

IMPORTANT NOTE: If you are planning to vent through the rear
wall, and the ceiling height is 8 ft., the maximum installation height
is 33

above the cooking surface.

*Always refer to the cooktop or range installation instructions for

product-specific clearances.