Step 2, connect electrical, Installation instructions, Warning – GE Monogram ZVC36 User Manual

Page 18

Advertising
background image

18

Installation Instructions

STEP 2 CONNECT ELECTRICAL

Verify that power is turned off at the source.

WARNING:

If house wiring is not

2-wire with a ground wire, an electrician will need
to convert existing wiring to meet these specs.
When house wiring is aluminum, be sure to
use U.L.-approved anti-oxidant compound
and aluminum-to-copper connectors.

1. Place insert sleeve on padded, yet stable, surface

below cutout (can use flattened carton to pad
surface).

2. Remove the junction box cover.

3. Pull house wires through wall of insert sleeve and

attach the strain relief. Thread the house wire
through the junction box.

4. Connect white leads to branch circuit white lead.
5. Connect black leads to branch circuit black lead.
6. Connect green/yellow leads to branch circuit green

lead.

7. Secure all connections with wire nuts on each

electrical connector.

8. Carefully push wires into junction box and replace

cover.

9. Secure junction box cover with original screws.

Connect

Wires

Screws

Cover

Advertising