3 battery cable connections – Generac PRIMEPACT 50 04164-3 User Manual

Page 35

Advertising
background image

33

These generators are rated at about 100 DC amperes of cranking

current.
Select battery cables based on (a) cable length and (b) prevail-

ing ambient temperatures. Generally, the longer the cable and the

colder the weather, the larger the cable size must be, as shown in

the chart.

CABLE LENGTH

in Feet (meters)

CABLE SIZE

0 to 10 (0 to 3)

2*

11 to 15 (3.4 to 4.5)

0

16 to 20 (4.5 to 6)

000

*For warm weather, use No. 2 cable up to 20 feet.

2.8.3 BATTERY CABLE CONNECTIONS

‹

1. Connect the battery cable from the battery post or terminal

indicated by a POSITIVE, POS or (+) to the lug on the starter

contactor (Figure 2.20).

NOTE:

Check to be sure the battery cable boot for the starter cable has

been installed.
2. Connect the battery cable from the battery post indicated by a

NEGATIVE, NEG or (-) to the frame ground connection (Figure

2.20).

3. Connect cables so the connectors are clean and tight.

Figure 2.20 – Connecting Battery Cables

SIDE VIEW OF GENERATOR

STARTER
CONTACTOR

GROUND LUG

NEGATIVE CABLE

BATTERY

Section 2 – Installation

Recreational Vehicle Generator

Figure 2.19 – Installation With Isolation Receptacle

Advertising