5

Installation Instructions

PREPARE HOT WATER LINE

• The line may enter from either side, rear or fl oor within the

shaded area shown in Figure F.

• The line may pass through the same hole as the electrical

cable and drain hose. Or, cut an additional 1-1/2" dia. hole to
accommodate the water line. If power cord with plug is used,
water line must not pass through power cord hole.

Figure F

Water Line Connection

• Turn off the water supply.
• Install a hand shut-off valve in an accessible location, such

as under the sink. (Optional, but strongly recommended and
may be required by local codes.)

• Water connection is on the left side of the dishwasher. Install

the hot water inlet line, using no less than 3/8" O.D. copper
tubing. Route the line as shown in Figure F and extend
forward at least 18" from rear wall.

• Adjust water heater for 120°F to 150°F temperature.
• Flush water line to clean out debris.
• The hot water supply line pressure must be 20-120 PSI.

CAUTION:

Opening the door will cause the dishwasher
to tip forward.

Do not open the door

until you are ready

to install the dishwasher. If it is
necessary to open the door, hold
the top of the dishwasher securely
with one hand and hold the door
with the other hand.

STOP

BEFORE YOU BEGIN

Locate and set aside the package containing
2 Phillips head countertop mounting screws
and 2 additional toekick screws (located in
the literature package).

Figure G

STEP 1 CHECK DOOR BALANCE

To check the door balance, hold the top of the dishwasher
fi rmly.
• Check the door balance by opening and closing the door.
• If the door drops when released, increase the spring tension.

If the door rises when released, decrease the spring tension.

• Models have different spring mounting and tension methods.

Refer to the appropriate fi gure for your model.

Figure H

CAUTION:

The hot water supply line pressure must be at least 20 psi.
Lower pressures could cause the water valve to leak and
cause water damage.

Cabinet Face

Shut-off

Valve

3" From Floor

18" From Wall

2"

From

Cabinet

1-1/2" Dia.

Hole

Hot

Decrease

Increase

Increase

PDW1800_II models only

Increase

Decrease

Decrease