Generac 04389-1 User Manual

Page 28

Advertising
background image

26 Generac

®

Power Systems, Inc.

Section 6 — Electrical Data

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators
Electrical Schematic – 12 & 15 kW – Drawing No. 0D8501-A

IM1 - IGNITION MODULE, CYLINDER #1
IM2 - IGNITION MODULE, CYLINDER #2
LOP - LOW OIL PRESSURE SWITCH

SP1, SP2 - SPARK PLUGS
SW1 - AUTO / OFF / MANUAL SWITCH
SW2 - SET EXERCISE SWITCH
SM - STARTER MOTOR
TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA (DUAL SEC.)

CB1 - CIRCUIT BREAKER, MAIN OUTPUT

FS - FUEL SOLENOID
F1 - FUSE 15 AMP

HTO - HIGH OIL TEMPERATURE SWITCH

BCR - BATTERY CHARGE RELAY

DIAGRAM KEY

SC - STARTER CONTACTER

2

1

5

3 4

J2

2

1

3

2

1

8

14

17

15

13

12

10

J1

7

5
6

3
4

1

F2 - FUSE 5 AMP

BA - BRUSH ASSEMBLY

CB2 - CIRCUIT BREAKER, ALT. EXCITATION
D - DIODE

SCR - STARTER CONTACTOR RELAY

2

23

224

77

FIELD

11

4

22

6

162

REGULATOR

ELECTRONIC

VOLTAGE

0

0

22

0

11

0

13A

66

0

85

HTO

0

6

4

WINDING

13A

77

66

BCR

LOP

351

4

SW2

86

225

0

0

13A

224B

BATTERY

CHARGER

225B

22

11

F1

CONTROL

BOARD

PRINTED CIRCUIT

66A

225

224

17

15

0

15A

194

23

14

86

4

18

56

194

0

14

14

CB2

55

F2

66A

66A

0

ENGINE RUN

WINDING

BATTERY CHARGE

13

0

C2-11

C2-4

0

C2-9

(STATOR)

C1-6

C2-7

C2-8

(STATOR)

C2-3

C1-4

C1-3

C2-1

BA

C2-2

7

1

7

6

9

3

9

4

224A

225A

0

Advertising
This manual is related to the following products: