Ir remote control unit configuration – Gefen GTB-MHDMI1.3-441 User Manual

Page 13

Advertising
background image

10

IR REMOTE CONTROL UNIT CONFIGURATION

Resolving IR Code Confl icts

In the event that IR commands from other remote controls confl ict with the
supplied IR remote control unit, changing the remote channel will alleviate this
issue. The IR remote control unit has a bank of DIP switches for setting the
remote IR channel.

The DIP Switch bank on the IR remote control unit is located underneath the
battery cover.

It is important that the IR channel selected on the remote, match the IR channel
on the GefenToolBox 4x1 Switcher for HDMI for proper operation. For example,
if you set both DIP switches on the remote to the down position (toward the “1”
and “2”), IR channel 0, you must set the GefenToolBox 4x1 Switcher for HDMI to
use IR channel 0.

1 2

1 2

1 2

1 2

Remote Channel 2:

Remote Channel 0:
Default

Remote Channel 1:

Remote Channel 3:

DIP Switches

See page 16 for information on how to change the IR channel on the
GefenToolBox 4x1 Switcher for HDMI.

Advertising