Rs-232 serial control – Gefen GTB-MHDMI1.3-441 User Manual

Page 16

Advertising
background image

13

5 4 3 2 1

9 8 7 6

1 2 3 4 5

6 7 8 9

Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface

This feature allows for easy integration into automated systems capable of
transmitting RS-232 commands. Please use the settings listed below to
confi gure the RS-232 port of the user’s system.

Transmitting the appropriate numeric ASCII character will simulate key presses
on the RMT-4IR remote control.

Binary Table

ASCII

RMT-4IR

Button

Binary

1

1

0011 0001

2

2

0011 0010

3

3

0011 0011

4

4

0011 0100

RS-232 Settings

Bits per second ................................................................................................. 19200

Data bits .................................................................................................................... 8

Parity .................................................................................................................. None

Stop bits .....................................................................................................................1

Flow Control ....................................................................................................... None

RS-232 SERIAL CONTROL