Edid modes – Gefen EXT-DVIKVM-841DL User Manual

Page 15

Advertising
background image

11

EDID MODES

EDID Modes
The diagram below illustrates the 4 DIP switch bank. The 8 DIP switch bank

functions are outlined later on this page.

DIP SWITCH

Function

1

IR Channel

2

IR Channel

3

EDID Mode

4

EDID Lock Mode

Use DIP switch 3 to set the desired EDID mode.

1. LOCAL EDID Mode (Switch 3=OFF) DEFAULT

EDID that is stored in the LOCAL memory location is passed to all inputs.

By default, during each power on process the connected display’s

EDID will be automatically copied to each of the input’s LOCAL EDID

locations.*

The EDID stored in the LOCAL locations can be overwritten with another

EDID from the following locations (These options can only be initiated by

using RS-232 serial communication commands) :

Built-in EDID memory bank (up to 7 EDID records can be stored)

EDID collected directly from the input display*

Externally uploaded via the RS-232 command set (see p. 13)

*For the default EDID writing process to be successful the connected display

must be powered on.

2. DS (Down Stream) EDID Mode (Switch 3=ON)

EDID is passed directly from the connected display to the currently active

input.

Note: HDCP is supported in this mode only.

3. EDID Lock Mode (DIP Switch 4 = ON)

Locks the last stored EDID, even if the unit is power-cycled. To store a

new EDID, do the following:

1. Power-down the Switcher and set DIP Switch 4 to the OFF position.

2. Connect the display to the DVI output port then power-on the Switcher.

3. Set DIP Switch 4 to the ON position to lock the EDID.

1 2 3 4