Enter the sensor number as 0 (no sensor) and press, Press * + 00 + # to exit the programming menus, Installer programmable lighting – GE 4 Series User Manual

Page 33: Controlling outputs by time schedule, Press 065, The touchpad displays “outputs.” press, Enter, Scheduled arming, Note schedules cannot be used to disarm the system, Press 0660

Advertising
background image

Concord 4 Series Security Systems

23

3. Press

A

or

B

until the light number (1–9) you would like to activate appears.

4. Enter the sensor number (1–96 for Concord 4, 1-32 for Concord Express V4) you wish to

activate the light and press

#

.

5. Press

B

to assign another light to a sensor or press

*

+

00

+

#

to exit the programming

menus.

To detach lights from sensors:

1. At an alphanumeric or fixed display touchpad, enter the programming menus by pressing

9

+

System or Partition Master

CODE

.

2. Press

B

until the touchpad displays “ATTACH LIGHTS TO SENSORS” or “LITE TO SN”

then press

#

.

3. The touchpad displays “LIGHT n TO Sn x” or “LT n SN x,” (where n is the light number and

x is the sensor number).

4. Press

A

or

B

until the light number (1–9) you would like to deactivate appears.

5. Enter the sensor number as 0 (no sensor) and press #.
6. Press

*

+

00

+

#

to exit the programming menus.

Installer Programmable Lighting

If you would like specific lights to turn on during Entry and Exit Delay times, or if you would

like a light to flash to indicate successful arming and disarming, contact your installer.

Controlling

Outputs by

Time Schedule

Outputs may be used to control devices in your home such as automatic window blinds. Outputs

that your installer has enabled, can be turned on or off according to time schedules. If you need

assistance setting up a time schedule that fits your needs, see “Creating Time Schedules”.

To schedule outputs:

1. At an alphanumeric or fixed display touchpad, enter the programming menus by pressing

9

+

System or Partition Master

CODE

.

2. Press

065

+

#

3. The touchpad displays “OUTPUTS.” Press

#

.

4. Press

B

until the touchpad displays the output number you would like to schedule. Refer to

“Appendix A: User Sheets” to determine which output is associated with which output num-

ber.

5. Press

#

. The touchpad displays the first available time schedule.

6. Enter

2

+

#

to assign the time schedule (“ON”) for this output.

1

+

#

to make the time schedule inactive for this output.

7. Press

B

to go to the next time schedule, if needed, and turn the schedule on or off for this out-

put.

8. When you’ve finished attaching the desired time schedules, press

*

+

00

+

#

to exit the pro-

gramming menus.

Scheduled

Arming

The Scheduled Arming feature allows the panel to be armed to Level 3—AWAY according to a

schedule. When an active schedule start time is reached the panel will exit User Programming,

automatically bypass any open sensors, and arm to Level 3—AWAY.
The panel will not arm according to an active schedule if the start time is reached while:
• The panel is already armed to Level 3—AWAY.
• The panel is performing a phone or sensor test.

Note

Schedules cannot be used

to disarm the system.

To schedule arming:

1. At an alphanumeric or fixed display touchpad, enter the programming menus by pressing

9

+

System or Partition Master

CODE

.

2. Press

0660

+

#.

3. The touchpad displays “AWAY.”

Advertising