Common questions and answers, Phone issues, Lighting issues – GE 4 Series User Manual

Page 50: Phone issues lighting issues

Advertising
background image

Concord 4 Series Security Systems

40

Common Questions and Answers

Q. I can’t arm my system.
A. Try the following:
• If arming to Level 2—STAY or Level 3—AWAY, make sure all monitored perimeter doors

and windows are closed.

• Press

*

for a system status and for clues to the problem.

• Call the installer.
Q. I cannot bypass a sensor: my alphanumeric touchpad displays “INVALID” and my fixed dis-

play touchpad sounds a single, long beep.
A. Possible explanations include:
• The sensor you’re trying to bypass may not be active in the current arming level. For exam-

ple, an interior motion detector will not be active in Level 2—STAY.

• You may be trying to bypass a 24-hour sensor that cannot be bypassed, such as a smoke

detector.

• Your access code has not been assigned the direct bypassing attribute. See “Assigning the

Direct Bypassing Attribute”.

Q. I can’t arm my system to Level 3—AWAY.
A. If a delay door is open while you’re trying to arm the system to Level 3 or a delay door was

not activated after the arming attempt, the system will arm to Level 2 instead. Close the delay

door, arm the system to Level 3, then exit through a delay door.

Phone Issues

Q. How do I disable my system long enough to retrieve messages from work or to do banking

over the phone?
A. Solutions include:
• Disengage the security system from local phone control by entering

#

+

7

+

3

. The system

responds by returning a dial tone.

• Pick up the phone receiver and wait 5 seconds before dialing any numbers. After the 5 second

period, the system disables local phone control and ignores phone commands.

Lighting Issues

Q.My lights don’t come on automatically as they’ve been programmed to do.
A.Try the following:
• Does the lamp have a working bulb?
• Is the lamp plugged in at a working outlet that is not controlled by a light switch?
• Is the lamp plugged in to a lamp module?
• Make sure that you’ve attached the correct time schedule as described in “Advanced Light

Control”.

• Check to see that you’ve set up the time schedule correctly as described in “Creating Time

Schedules”.

• Check the User Sheets in Appendix A to see in which partition the light is set up to be active.