U s er ies 24" g as r estaurant r ange – Garland Enodis U24-4L User Manual

Page 2

Advertising
background image

Garland Commercial

Industries, LLC

185 East South Street

Freeland, PA 18224

Phone: (570) 636-1000

Fax: (570) 636-3903

Garland Commercial Ranges Ltd

1177 Kamato Road,

Mississauga, Ontario

L4W 1X4 CANADA

Phone: 905-624-0260

Fax: 905-624-5669

Enodis UK LTD

Swallowfield Way,

Hayes, Middlesex

UB3 1DQ ENGLAND

Telephone: 081-561-0433

Fax: 081-848-0041

34-1/2"

[876mm]

1-1/2"

[39mm]

3/4" N.P.T.

REAR GAS

INLET

23"

[586mm]

2-1/4"

[57mm]

27-1/4"

[692mm]

5"

[127mm]

23-5/8"

[600mm]

21"

[534mm]

30"

[763mm]

6"

[152mm]

12-1/8"

[307mm]

18-3/8"

[466mm]

13-7/8"

[352mm]

ADD WHEN

DOOR OPEN

31-1/8"

[791mm]

39-3/8"

[1000mm]

LOW PROFILE

BACKGUARD

51"

[1296mm]

STD BACKGUARD

W/HIGH SHELF

U S
er

ies 24" G

as R
estaurant R

ange

Form# U24 series (09/02/08)

Model

Number

Description

Total

BTU/Hr

Natural

Gas

Shipping Information

Lbs.

Kg

Cu Ft

U24-4L

Four Open Burners w/Space Saver Oven

160,000

302

137

26

U24-4S

Four Open Burners w/Storage base

128,000

221

100

26

U24-2G12L

12" Griddle, Two Open Burners w/Space Saver Oven

114,000

332

151

26

U24-2G12S

12" Griddle, Two Open Burners w/Storage base

82,000

251

114

26

U24-24GL

24" Griddle w/Space Saver Oven

68,000

367

166

26

U24-24GS

24" Griddle w/Storage Base

36,000

286

130

26

Width

Depth

Height

w/Shelf

Oven Interior

Combustible Wall Clearance

Entry Clearances

Height

Depth

Width

Sides

Rear

Crated

Uncrated

23-5/8"

(600mm)

34-1/2"

(876mm)

57"

(1448mm)

13"

(330mm)

26"

(660mm)

20"

(508mm)

14"

(356mm)

6"

(152mm)

25"

(635mm)

24-1/2"

(622mm)

Burner Ratings (BTU/Hr/kW)

Gas

Open Top

Griddle/Hot Top

Oven

Natural

32,000/9.37

18,000/5.27

32,000/9.37

Propane

26,000/7.61

18,000/5.27

28,000/8.20

Manifold

Operating Pressure

Natural

Propane

4.5" WC

11 mbar

10" WC

25 mbar

Note: Installation clearance reductions are appli-

cable only where local codes permit.

Gas input ratings shown for installations up to

2000 ft.,(610m) above sea level. Please specify

altitudes over 2000 ft.

This product is not approved for residential use.