3

Volume ........................................................................................................ Up to19.0 GPM

Discharge Pressure .................................................................................... Up to 2900 PSI

Inlet Pressure.............................................................................................. Up to 90 PSI

Speed .......................................................................................................... Up to 1000 RPM

Plunger Diameter ........................................................................................ 28 mm

Stroke .......................................................................................................... 42 mm

Crankcase Oil Capacity .............................................................................. 100 fl.oz.

Temperature of Pumped Fluids ................................................................... Up to 140

o

F

.................................................................................................................... 160

0

F up to 500 RPM

Inlet Port ..................................................................................................... (3) x 1-1/2" BSP

Discharge Port ............................................................................................ (3) x 1" BSP

Crankshaft Mounting .................................................................................. Either Side

Shaft Rotation ................................................................................ Top of Pulley Towards Fluid End

Weight ......................................................................................................... 116 lbs.

Crankshaft Diameter .................................................................................. 35 mm

Specifications

Model LP200

* Intermittent duty for pump speeds in excess of 805 RPM

HORSEPOWER INFORMATION

We recommend that a 1.1 service factor be

specified when selecting an electric motor as

the power source. To compute specific pump

horsepower requirements, use the following

formula:

HP = (GPM X PSI) / 1440

PULLEY INFORMATION

Pulley selection and pump speed are based on

a 1725 RPM motor and "B" section belts. When

selecting desired GPM, allow for a ±5% toler-

ance on pumps output due to variations in

pulleys, belts and motors among manufactur-

ers.

1.Select GPM required, then select appropriate

motor and pump pulley from the same line.

2.The desired pressure is achieved by selecting

the correct nozzle size that corresponds with

the pump GPM.

LP200 HORSEPOWER REQUIREMENTS

RPM GPM 1000 PSI 1500 PSI 2000 PSI 2900 PSI

500

9.5

6.6

9.9

13.2

19.2

640

12.2

8.5

12.7

16.9

24.6

750

14.3

9.9

14.9

19.8

28.8

805

15.3

10.6

16.0

21.3

30.9

865

16.5

11.4

17.2

22.9

33.2

920

17.5

12.2

18.3

24.3

35.3

1000 19.0

13.2

19.8

26.5

38.4

Advertising