Specifications

Model LP250, LP250W-MT

Volume ........................................................................................................ Up to 26.0 GPM

Discharge Pressure .................................................................................... Up to 2200 PSI

Inlet Pressure.............................................................................................. Up to 90 PSI

Speed .......................................................................................................... Up to 1000 RPM

Plunger Diameter ........................................................................................ 32 mm

Stroke .......................................................................................................... 42 mm

Crankcase Oil Capacity .............................................................................. 100 fl.oz.

Temperature of Pumped Fluids ................................................................... Up to 140

o

F

Inlet Port ..................................................................................................... 1-1/24" BSP

Discharge Port ............................................................................................ 3 x 1" BSP

Crankshaft Mounting .................................................................................. Either Side

Shaft Rotation ................................................................................ Top of Pulley Towards Fluid End

Weight ......................................................................................................... 110 lbs.

Crankshaft Diameter .................................................................................. 35 mm

* Intermittent duty for pump speeds in excess of 805 RPM

PULLEY INFORMATION

Pulley selection and pump speed are based on

a 1725 RPM motor and "B" section belts. When

selecting desired GPM, allow for a ±5% toler-

ance on pumps output due to variations in

pulleys, belts and motors among manufactur-

ers.

1.Select GPM required, then select appropriate

motor and pump pulley from the same line.

2.The desired pressure is achieved by selecting

the correct nozzle size that corresponds with

the pump GPM.

HORSEPOWER INFORMATION

We recommend that a 1.1 service factor be

specified when selecting an electric motor as

the power source. To compute specific pump

horsepower requirements, use the following

formula:

HP = (GPM X PSI) / 1440

LP250 HORSEPOWER REQUIREMENTS

RPM GPM 1000 PSI 1500 PSI 2000 PSI 2200 PSI

500

13.0

9.0

13.5

18.0

19.8

640

16.6

11.5

17.3

23.1

25.4

750

19.5

13.5

20.3

27.1

29.8

805

20.9

14.5

21.8

29.0

31.9

865

22.5

15.6

23.4

31.2

34.3

920

23.9

16.6

24.9

33.2

36.5

1000 26.0

18.0

27.1

36.1

39.7