Installation instructions, Site requirements, Technical specifications – Stovax Electric Stove Range User Manual

Page 9

Advertising
background image

9

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATIONS

SITE REQUIREMENTS

These appliances have 3 modes of operation:

a) flame effect only - with brightness and flame speed

adjustment

b) flame effect + 1kw heating

c) flame effect + 2kw heating

ALL 'INGLENOOK' FIREPLACE OPENINGS:

FOR ALL MODELS, THE DIMENSIONS REQUIRED FOR AN

'INGLENOOK' TYPE OF INSTALLATION CAN BE CALCULATED

BY ADDING 225 mm (9") TO THE HEIGHT AND 150 mm (6")

TO EACH SIDE, ADDING 300 mm (12") TO THE APPLIANCE

WIDTH. AN ADDITIONAL 50mm (2") MUST BE ADDED TO

THE DEPTH DIMENSION TO PROVIDE ADEQUATE SPACE

BEHIND THE APPLIANCE.

KEY TO SUFFIXES

Anthracite =

AN

Midnight Blue =

B

Stainless Steel =

BS

Ivory =

V

Matt Black =

None

Laurel =

LG

A 230v 13amp 50Hz supply is required.

Maximum power consumption: 2064 watts.

THIS APPLIANCE MUST BE EARTHED

A 1.8 metre plug and lead are supplied

Bulb types: 2 X 40 watt ‘Elegance’ Soft E.S. (E14) candle

lamp (fused)

Remote control handset battery (CR2025)

Manhattan Small

E8622 / AN / BS

Clarendon Medium Clear

E8612 / B / LG

Manhattan Medium

E8619 / AN / BS

Huntingdon

E8503 / B / LG / V

Ashdon Medium

E8613 / B / LG / V Marlborough Small

E8560

Clarendon Small

E8517

Marlborough Medium

E8610

Clarendon Medium

E8612

Stockton Small

E8573

Clarendon Small Clear

E8517 / B / LG

Stockton 5 (Midi)

E8575

Stockton Medium

E8617

These instructions cover the following models:

SMALL MARLBOROUGH DIMENSIONS

1

410mm

533mm

280mm

80mm

Advertising