Countdown display, Dccd models only) – GE DCCD330 User Manual

Page 7

Advertising
background image

7

Safety Instructions

Care and Cleaning

Consumer Support

Operating Instructions

Countdown display.

(DCCD models only)

ge.com

The countdown display shows the remaining operating time as well as the current drying cycle. The
display board is configured for a 45-minute dry time at the factory to correspond with the 45-minute
timer cam pre-installed in the coin box. If the timer cam is modified for another operating duration,
the dip switches on the display board should be set as follows:

NOTE: This display does not accumulate time. See the following examples of display possibilities.

DIP SWITCH NUMBERS

DRYING TIME (minutes)

1

2

45

1

1

60

1

0

90

0

1

120

0

0

DIP SWITCH SETTING (min)

COIN SLIDE ACTUATIONS

DISPLAY READING (min)

45

1

45 to 0, then blank

45

2

45 to 1, then 1 for next 45 min.,
then 0 and blank

120

1

99 for 21 minutes, then 98 to 0,
then blank

Advertising