12 volt dc, 10 amp receptacle – Generac 7000exl User Manual

Page 10

Advertising
background image

Generac Portable Products 7000EXL Extended Life Generator

10

120 Volt AC, 30 Amp Locking

Receptacle

Use a NEMA L5–30 plug with this receptacle. Connect a
3–wire cord set rated for 125 Volt AC loads at 30 Amps to
the plug (Figure 12).

Use this receptacle to operate 120 Volt AC, 60 Hz, single
phase loads requiring up to 3,600 watts (3.6 kW) of power
at 30 Amps.The outlet is protected by a 30 Amp
push–to–reset circuit breaker.

120 Volt AC, 20 Amp, Duplex

Receptacle

Each receptacle (Figure 13) is protected against overload by
a 20 Amp push–to–reset circuit breaker.

Use each receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).

12 Volt DC, 10 Amp Receptacle

This receptacle allows you to recharge a 12 Volt
automotive or utility style storage battery with the battery
charge cables provided (Figure 14).This receptacle can not
recharge 6 Volt batteries and can not be used to crank an
engine having a discharged battery. See the section
“Charging a Battery” (page 8) before attempting to
recharge a battery.

Figure 13 — 120 Volt AC, 20 Amp Receptacles

Figure 12 — 120 Volt, 30 Amp Receptacle

Figure 14 — 12 Volt DC, 10 Amp Receptacle